DISTILLERMEISTER E2-55 Premium-Plus Model 2026 - all inclusive
With everything you need for distilling, collecting, separating and analysing
You save more than €70 with this bundle
NEW! Silicone seals are no longer required
A stainless-steel still, optimised for the distillation of essential oils and not subject to registration, with a large capacity for flowers and leaves
The DESTILLIERMEISTER E2-55 Premium-Plus Model 2026 is a completely new version of the E2-55 Premium-Plus24 model and replaces it. The distillation process remains the same, but the design has been completely overhauled, significantly reducing both set-up and distillation times. A ‘tripod’ keeps the cooling system separate from the boiler system.
The ‘No-Worries’ package contains:
1 to 10. The distillation unit.
11. Distillate hose to fit onto the hydrolate outlet – may need to be shortened as described below. You can unscrew the hose and screw on a water hose with a 1/2" thread to clean the pipework.
Also included is a copper elbow to fit onto the hydrolate outlet
12. An oil separator.
13. An additional 500 ml Erlenmeyer flask with stopper
14. Cooling water supply set
15. For assessing hydrolate quality: pack of 100 pH test strips, pH 3.6 to 6.1.
16. Light-protective vials for essential oils, 2 each of 10 ml, 20 ml and 50 ml
17. Syringe with injection needle for drawing off or dispensing small quantities of oil
18. So you can get started straight away: 500 g of blue lavender flowers, distillation grade, in an aroma- and light-protective bag. This will give you at least one initial filling for the plant tube. The packaging is fitted with an aroma-seal lid, so that any leftovers can be stored safely. This gives you a guide to what your harvest should yield. Of course, this only applies to dried lavender flowers. Make sure you harvest at the right time; this is important for the yield. I go into this in more detail in the online quick guide.
The DESTILLIERMEISTER E2-55 Premium-Plus Model 2026 - all inclusive has a 2-litre water/steam boiler, which is filled to a maximum of 1.8 litres. The water supply is generally sufficient for one distillation, typically yielding 1 litre, up to a maximum of 1.5 litres. The plant tube is screwed onto the lid of the water boiler. To empty and refill the plant tube, it is best to open the clamps on the plant tube and lift the cooling system a few centimetres. You can then remove the boiler assembly. This procedure is illustrated below.
The cooling system operates using an effective counter-current process, as seen in a Liebig condenser. The concept behind the Premium model is the pre-condensation of the vapour in a pre-condenser, into which the vapour is fed directly behind the riser pipe without any reduction in the pipe cross-section and without any loss of pressure. Consequently, the steam does not have to flow against a pressure peak here, which would lead to oil losses. The temperature at the plants is also lower with the pre-condenser, which improves the quality of the essential oils.
To keep the system compact, both the pre-condenser and the final cooler are curved, unlike a Liebig cooler. This allows for a total cooling length of a good 1.5 m in a confined space, which is very convenient for operating with a low cooling water flow.
The rising tube and pre-condenser can be screwed together, making the system easier to handle and more versatile. A reduction in cross-section is only applied at the distillate inlet of the final cooler. However, this no longer results in a pressure loss, as the condensed vapour no longer occupies any significant volume.
The riser pipe on the Premium-Plus model is insulated to minimise condensate loss. Overall, the Premium-Plus model is therefore optimised for the extraction of essential oils and hydrolates. The cross-section is only reduced at the transition to the final cooler, but this no longer creates any flow resistance because the vapour has by this stage condensed.
Note: Pressure losses in the pipework system result in increased pressure within the plant tube; the vapour must therefore work against a pressure peak. This damages the essential oils, reduces their quality and also lowers the yield if the oils cannot overcome this pressure peak.
From previous experiments with the DESTILLIERMEISTER E2-55 Premium, we know that the optimal ratio of plant tube height to plant tube diameter has a positive effect on efficiency.
Due to the larger evaporation surface area of the water boiler, the distillation rate is significantly increased, which shortens the distillation time and reduces the duration for which the essential oils are exposed to a hot environment. This therefore also affects the quality of the distillates.
For the vast majority of plants and flowers, the water supply is sufficient for one distillation, yielding 1 litre of distillate per distillation. However, if the yield of one litre of hydrolat per distillation is insufficient – as we have observed, for example, when distilling fennel seeds – the water supply is sufficient for a further yield of 500 ml of hydrolat. Water can, however, be topped up via the filling nozzle 2.2. without having to open the kettle.
The insulated riser pipe already reduces condensate losses. These losses can be further reduced by also insulating the plant tube, e.g. with a blanket. This should then result in a higher oil yield.
With 5.5 litres of plant chamber capacity, you have ample space to process larger quantities of plants or herbal materials. By raising the aroma basket, you can also experiment with smaller quantities; however, you should then operate at a reduced heat setting to ensure the steam does not simply pass through the plant material without having any effect. As the steam is generated in a separate boiler beneath the herb chamber, there is no risk of coming into contact with boiling water. However, you should only fill the boiler with a maximum of 1.8 litres to allow the steam to build up inside the boiler and to prevent hot water from being drawn up in the event of delayed boiling.
Easy to use:
In the new model, optimised clamping mechanisms mean that seals are no longer required between the 1st and 2nd stages, or between the 3rd and 4th stages. The sealing is achieved by metal-to-metal contact. Consequently, there are no longer any ongoing costs associated with this model.
Fill the water/steam boiler with a maximum of 1.8 litres of water – either demineralised or distilled water, or tap water, provided that, after a few distillations, any limescale build-up is removed from the bottom of the boiler using lukewarm citric acid or heated acetic acid.
Fit the lid with the 3/4" screw connection and secure it with the clamping fasteners.
Place the aroma basket into the plant tube and open it out. Now fill the plant tube, press the contents down gently and connect it to the 3/4" screw connection.
The cooling system is fitted into the tripod as described and documented below:
Clamp the pre-condenser into the tripod as shown in the pictures below – ideally within the markings we have provided.
Screw the insulated riser pipe with the 3/4" thread onto the pre-condenser at 6.1.
Screw the plant tube cover at 5.1 onto the riser pipe.
Screw the final cooler at 6.4 onto the pre-condenser.
The water supply begins at the final cooler at 7.3. The cooling water then flows upwards between the pipe core and the pipe jacket towards the pre-condenser. From 7.4 to 6.3 (pre-condenser cooling water inlet), the cooling water is routed via the supplied hose 8 into the cooling water section between the pre-condenser core and the pre-condenser jacket. The outlet for the hot cooling water is at 6.4. A hose with a 3/4" screw connection must be fitted here. The cooling water therefore always flows in counter-current to the distillate flow, from bottom to top.
Switch on the heat source and collect the hydrolate with oil at 7.5.
With the plant tube fully filled, distil for a maximum of 20 minutes at high power (induction hob from 2000 watts, preferably 3000 watts) for most plants. For small quantities of plant material and with the aroma basket raised, use 1200 to 1500 watts. It is best to collect two fractions of 500 ml each in a sterile bottle. If the pH value of the second fraction does not differ significantly from that of the first and is below 6, further fractions may be collected.
The water/steam container and the plant/herb tube, as well as all distillate-carrying pipes, are made of high-quality stainless steel.
System configuration, illustrated using the 10-litre system as an example
Constuction
Water/steam boiler, 10.5 litres. Approximately 8 litres of water are added.
Cover with screw connection for the insulated riser pipe.
3/4" screw connection
Stainless steel analogue thermometer, accuracy class 1
Insulated riser pipe.
3/4‘ threaded nipple for connecting to 5.1.
Riser pipe with insulation.
3/4’ threaded connection for the pre-condenser. The red marking on the threaded connection continues onto the threaded nipple 7.1, so that the correct direction of rotation for the pre-condenser is indicated during initial assembly.
double-walled tube in counter-current configuration (outer jacket, inner core).
Cooling water inlet – cold, 1/2’ nipple.
Cooling water outlet; screw hose 8 onto this.
Distillate outlet. Fit distillate hose 11 onto this.
Cooling water connecting hose for connection to 7.4 and 6.3.
Tripod for supporting and securing the distillation set-up. The levers can be tightened by turning them clockwise.
4 support legs,
Folding lever for extending and retracting the support legs:
Unfold the lever,
extend the support legs,
fold the lever shut.
Socket for the tripod tube.
Lever for adjusting the working height:
Open the lever,
manually raise or lower the tripod tube,
close the lever.
Tripod tube.
Loosen the locking screw to adjust the angle of the pre-condenser bracket. Tighten it again.
The tubes must have a gradient in the direction of flow throughout.
Support arm for the cooling system.
Support sleeve with locking knob.
Aroma basket for insertion into the steam pipe.
This is positioned at a minimum distance of approximately 3 cm from the base and can be adjusted upwards for smaller quantities. It has a closed compartment in the centre, so that, when in the lower position, the rising steam jet does not flow directly through the plant material and create a tunnel due to the jet effect, which would result in significant losses. Due to the baffle, the steam initially flows radially and then rises due to its own thermal convection. The plant tube has a height-to-diameter ratio greater than 1, so that an effective chimney effect promotes the entrainment effect.
Distillate hose and/or adapter to fit onto the system and, if necessary, cut to length as described above.
The hose can be unscrewed and a water hose with a 1/2" thread screwed on to clean the pipework.
Oil separation device, consisting of the following components
The separation funnel. This initially collects the hydrolate.
PTFE valve. In the picture, this is set to maximum flow. When rotated by 90°, it closes completely. It is closed at the start of distillation. Once approximately 60 to 70 ml has been collected, open it slowly and allow the hydrolate to drain off. Ideally, the hydrolate should flow into the collecting flask at the same rate as it flows into the separating funnel. The oil collects on the surface of the hydrolate in the separating funnel.
Stopper for the collecting flask with a passage. In the newly supplied kits, this stopper is replaced by a rubber stopper, as this is more stable. Pressure equalisation must be achieved here so that the hydrolate can flow out without bubbles. To do this, a notch is carved from top to bottom into the rim of the stopper. This is sufficient for pressure equalisation.
Receiving flask (Erlenmeyer flask). You should definitely distil 500 ml; the water-insoluble essential oil has now been almost completely distilled off. If you wish to continue collecting hydrolat, you should briefly switch off the heat source, decant the hydrolat or place a new flask underneath. Do not forget to close the tap 9.2 whilst doing this.
Sealing stopper, fitting the separating funnel. This is not required during distillation.
Additional 500 ml Erlenmeyer flask with stopper
Set for the cooling water supply with the following accessories
20-litre plastic bucket as a cooling water reservoir.
Powerful 230-volt cooling water pump with accessories for different hose diameters, sufficient for all our stainless steel stills up to approximately 20 litres.
Various 2-metre PVC hoses, including 2 hoses with hose fittings for the still cooler, one of which is prepared for connection to the pump. In addition, 3 hoses of varying thicknesses for different applications, e.g. hose extensions or decanting hydrolates, etc.
Plastic tap for regulating the cooling water, suitable for the counter-current cooler.
A graduated 100 ml measuring cylinder with a base, for taking distillate samples, e.g. to measure the pH value.
A cleaning brush.
A floating thermometer for monitoring the cooling water, in case the hot waste water is allowed to flow back into the bucket. From 40°C onwards, the water should either be cooled with ice or replaced.
A roll of Teflon tape for sealing, e.g. in case a seal fails during distillation.
pH test strips, pH range 3.6 to 6.1, 100 strips.
A hydrolate with a pH below 4 is of very high quality. From a pH of 6 or above, you should decide whether to stop the distillation. The hydrolate still smells lovely at this stage, but it no longer keeps as well.
Light-protective bottles for essential oils
2 each of 10 ml, 20 ml and 50 ml for storage, with original caps for gifting or selling, as well as dropper inserts for dispensing. With an original cap, the seal must be broken the first time it is used.
Syringe with injection needle for drawing up or dispensing small quantities of oil
Addition: 500 g of blue lavender flowers, to try out the still straight away
Test run
Heat source: Induction, power after heating time (approx. 3 mins) 3000 watts
Plant material: Dried lavender flowers
Quantity: 500 g
Total distillation time: 18 mins
Hydrolate collection: 2 batches, one every 9 mins
Batch: 500 ml after 9 mins, oil yield 30 ml, hydrolate pH: 3.2
Batch: 500 ml after a further 9 mins, oil yield approx. 1 ml, hydrolate pH: 3.8
Important note:
Under the new German Alcohol Tax Act, this still has also been legally available for sale in Germany since 1 January 2018 without the need to register with the authorities. Please note that, as a retailer, we are obliged to point out that this still may only be used for the distillation of distilled water, hydrolates, essential oils, flavourings, fragrances, perfumes and foodstuffs, for alchemical experiments, etc., or as a collector’s item.